Total dynamic head (Htotal)
—
Formula
The total dynamic head is calculated as:
Htotal = Hstatic + Hpressure + Hfriction + Hreserve
Where:
- Hstatic = discharge level − suction level [m]
- Hpressure = required pressure converted to liquid head [m]
- Hfriction = pipe and fitting losses [m]
- Hreserve = additional margin or process allowance [m]
Engineering note